PW3390 시리즈로 변경

제조사
HIOKI
제품명
POWER ANALYZER 3390(PW3390 시리즈로 변경)
제품번호
3390

견적문의 카달로그

PRODUCT INFO. 제품상세정보

● 현대의 까다로운 요구를 충족 시켜줄 ±0.1% 고정확도 모델
● 다른 Range를 선택하여도 여전히 모든 Range에 동일한 ±0.1% 정확도 유지
● 고급 모터 분석 기능 (electric angle and supports vector control 측정)
● 고속 고조파 분석기능 (50ms로 데이터 갱신)
● 인버터의 노이즈 분석기능(FFT분석 기술 사용)
● 클램프센서 사용으로 편리한 인버터 전력 측정

PRODUCT INFO. 제품상세정보

Measurement line type

Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire, Voltage 4 channels, Current 4 channels, Isolated between each channel

Measurement items

Voltage, Current, Voltage/current waveform peak, Active power, Reactive power, Apparent power, Power factor, Phase angle, Frequency, Current integration, Power integration, Efficiency, Loss, Voltage/current ripple factor
Noise measurement (FFT processing): RMS spectrum of voltage/current
Harmonic measurement: RMS value, Content factor, Phase angle, Total distortion, Disequilibrium factor
Additional functions (With optional 9791 or 9793 installed in the main unit) : Torque, Rotation, Frequency, Slip, or Motor output

Harmonic measurement

Input: 4 ch, Synchronization frequency range: 0.5 Hz to 5 kHz,
Number of harmonic orders: Max. 100th order

Noise measurement

Number of channels: 1 ch (select one channel from CH1 to CH4),
Maximum analysis frequency: 100 k/ 50 k/ 20 k/ 10 k/ 5 k/ 2 kHz

Measurement range

Voltage range: 15 to 1500 V, 7 ranges
Current range: 400 mA to 500 A (depends on current sensor, 20A/ 50A/ 200A/ or 500A rated)
Power range: 6.0000 W to 2.2500 MW (depends on combination of voltage and current range)
Frequency range: 0.5 Hz to 5 kHz

Basic accuracy (45Hz to 66Hz)

Voltage: ±0.05 % rdg. ±0.05 % f.s.
Current: ±0.05 % rdg. ±0.05 % f.s. (Defined at combined accuracy with dedicated sensors)
Active power: ±0.05 % rdg. ±0.05 % f.s. (Defined at combined accuracy with dedicated sensors)
Note: Accuracy for the high accuracy Models 3390-10 and Current Sensors are not defined individually. Please use these products in combination to obtain ±0.1% accuracy.

Synchronization frequency range

0.5 Hz to 5 kHz

Frequency band

DC, 0.5 Hz to 150 kHz

Data update rate

50 ms (For harmonic measurement, depends on the synchronization frequency when less than 45 Hz)

Display refresh rate

200 ms (Independent of internal data update rate; waveform and FFT depend on the screen)

Data save interval

OFF, 50 msec to 500 msec, 1 sec to 30 sec, 1 minute to 60 minutes, 15 settings

External interfaces

LAN, USB (communication/ memory), RS-232C, CF card, Synchronization control

Power supply

100 to 240 V AC, 50/60 Hz, 140 VA max.

Dimensions and mass

340 mm (13.39 in) W × 170 mm (6.69 in) H × 157 mm (6.18 in) D, 4.8 kg (169.3 oz)

Accessories

Instruction Manual for Model 3390-10 × 1, Instruction Manual for Model 3390 × 1, Power cord × 1, Measurement Guide × 1, USB cable × 1, Measurement cable label sheet × 2, D-sub connector × 1 (when 9792 or 9793 is installed)

 

■ Specifications for the Motor Testing Option (Accuracy guaranteed for 6 months, Post-adjustment accuracy guaranteed for 6 months)

Number of input channels

3 channels, CH A: Torque signal input (DC V / Frequency input), CH B: Rotation signal input (DC V / Pulse input), CH Z: Z-phase signal input (Pulse input)

Measurement item

Voltage, Torque, Rotation, Frequency, Slip, Motor power

DC V (CH A/B)

Measurement range: ±1 V/ ±5 V/ ±10 V, Accuracy: ±0.1 % rdg. ±0.1 % f.s.

Frequency (CH A)

Effective amplitude range: ±5 V peak, Measurement band: 1 kHz to 100 kHz

Pulse (CH B)

Detection level: (Low) 0.5 V or less, (High) 2.0 V or more, Measurement band: 1 Hz to 200 kHz

Pulse (CH Z)

Detection level: (Low) 0.5 V or less, (High) 2.0 V or more, Measurement band: 0.1 Hz to 1 kHz


PRODUCT INFO. 제품상세정보


3390_o.jpg