FEATURES - The big digital and bar graph LCD display with back light enabled easy observation. Especially useful when working in dark place.
- Hand free and continuous measurements with custom made switch.
- Safe design with built in automatic discharging function for any capacitors present in the circuit.
- The voltage in the circuit or capacitor can be checked by warning lamp for safe insulation measurements.
- Data hold and auto power off function.
- Compact, light weight and heavy duty rugged case.
|
SPECMeasuring Ranges and Technical Data |
---|
Insulation resistance |
---|
Model | MIS-2D | MIS-3D | MIS-4D |
---|
Rated voltage and effective measuring range | 125V-20MΩ 250V-50MΩ 500V-100MΩ | 250V-50MΩ 500V-100MΩ 1000V-2000MΩ | 125V-20MΩ 250V-50MΩ 1000V-2000MΩ |
---|
Minimum measurable resistance at rated voltage | 0.125MΩ 0.25MΩ 0.5MΩ | 0.25MΩ 0.5MΩ 1MΩ | 0.125MΩ 0.25MΩ 1MΩ |
---|
Rated current | 1mA+20%-0% |
---|
Open circuit voltage | Rated voltage+30%-0% |
---|
Short circuit current | <2mA |
---|
| | SPECIFICATIONS |
---|
Function | : | Insulation resistance, AC voltage |
---|
Display | : | 3.5 digit LCD with bar graph display, max. reading of 3200 count and annunciators |
---|
Safety standard | : | IEC 61010-1 Installation categoryⅡ, 600V phase to earth. |
---|
E.M.C. standard | : | EN 61326 |
---|
Response time | : | Less than 5 sec. (Auto ranging) |
---|
Data hold indication | : | "DH" mark on LCD readout |
---|
Infinity indication | : | "OL" mark on LCD readout (Over 3200 count) |
---|
Constructional standard | : | In accordance with IEC1557-2 or JIS C1302 (1994) |
---|
Withstanding voltage | : | AC 3700V, 1 minute (Between input terminal and outer case) |
---|
Overload protection | : | 120% of the highest nominal output voltage (10 sec.) |
---|
Battery check | : | DC 6.3V~9.5V |
---|
Low battery indication | : | Battery mark on LCD readout |
---|
Operating temperature | : | 0℃ to 40℃, 80% RH max. (Without condensation) |
---|
Temperature characteristics (0~40℃) | : | ±5% rdg of specified accuracy |
---|
Storage temperature | : | -10℃~60℃, 80% RH max (Without condensation) |
---|
Power supply | : | 1.5V (AM-3, R6 or "AA" size)×6 |
---|
Size | : | 170(W)×105(D)×54(H)mm |
---|
Weight | : | Approx. 330g (Excluding batteries) |
---|
Accessories | : | Line test lead | : | 1 | Earth test lead | : | 1 | Batteries | : | 6 | Test lead case | : | 1 | Belt | : | 1 | Instruction manual | : | 1 |
|
---|
Optional accessory | : | Test probe with remote switch |
---|
| Accuracy |
---|
Rated voltage | DC 125V | DC 250V | DC 500V | DC 1000V |
---|
Measuring range | 0~20MΩ~OL(∞) | 0~50MΩ~OL(∞) | 0~100MΩ~OL(∞) | 0~2000MΩ~OL(∞) |
---|
First effective range | 0.02MΩ~10MΩ <±5%rdg | 0.05MΩ~20MΩ <±5%rdg | 0.1MΩ~50MΩ <±5%rdg | 2MΩ~1000MΩ <±5%rdg |
---|
Second effective range | 0.01MΩ~0.02MΩ 10MΩ~20MΩ <±10%rdg | 0.02MΩ~0.05MΩ 20MΩ~100MΩ <±10%rdg | 0.05MΩ~0.1MΩ 50MΩ~100MΩ <±10%rdg | 1MΩ~2MΩ 1000MΩ~2000MΩ <±10%rdg |
---|
Other range | 100MΩ~OL(∞) :Accuracy is not Specified |
---|
| | AC voltage (50/60Hz) |
---|
Range | Accuracy | Input impedance | Maximum input voltage |
---|
AC 600V | ±2.5% of full scale | Approx. 20M | AC 600V rms |
| |
|